Climaflex Pipe Insulation 22mm x 13mm
£2.64 inc VAT (£2.20 ex VAT)
✓ In Stock
Free Click and Collect, no minimum order, from our Glasgow counter at 555 South Street, G14 0QX. Open Mon-Fri 8am-5pm, Sat-Sun 8am-1pm.
Collection only. This item is not sent by courier. Order online and collect it from our counter at 555 South Street, Glasgow G14 0QX. Delivery and Returns
Trade and public welcome at 555 South Street, Glasgow G14 0QX. Call 0141 404 5128.
For 22mm heating and water pipe, Climaflex pipe insulation 22mm x 13mm gives a 13mm foam wall in 2m tubes. It is the standard choice for heating primaries and cylinder pipework. From Plumb Parts in Glasgow.
| SKU | Thumbnail | Length | Delivery Details | Price | Quantity | Total | ||
|---|---|---|---|---|---|---|---|---|
| PF22132C |
|
2m | In Store Collection Only | £2.64 inc VAT (£2.20 ex VAT) |
-
+
|
£2.64 inc VAT |
Heating primaries and cylinder pipework are usually 22mm, and Climaflex pipe insulation 22mm x 13mm is the standard lagging for them. Each 2 metre tube has 13mm of foam all round.
Climaflex pipe insulation on 22mm pipe
The pipes between the boiler and the cylinder carry a lot of heat. Left bare, they warm the airing cupboard and the floor void instead of the water. Lagging them keeps more heat where it is meant to go, so the cylinder heats faster. It also suits 22mm cold mains running through a loft.
- Bore: 22mm
- Wall thickness: 13mm
- Length: 2m
- Closed cell polyethylene foam
Start at the boiler end and work along, butting each length tight to the last. Tape the joints and any slits. Cut the foam neatly round pump valves and zone valves, so they can still be worked. Keep it a little back from the boiler casing if the instructions ask for clearance. A neat, fully lagged cupboard also makes leaks easier to spot later.
Heating lagging at our Glasgow counter
Other wall thicknesses are listed under pipes, hoses and insulation.
Trade and DIY customers can call at Plumb Parts, 555 South Street, Glasgow G14 0QX. Visit Mon-Fri 8am-5pm or Sat-Sun 8am-1pm, or order online.
Specification
- Brand: Climaflex
- Material: Closed cell polyethylene foam
- Sizes: 22mm bore, 13mm wall, 2m lengths
- Suitable for: Insulating 22mm pipe
- Standard/approval: Fire class Euroclass E (EN 13501-1)
- Max temperature: 0°C to +100°C
Common Questions
Why lag the 22mm primaries between boiler and cylinder?
Bare primaries lose heat into the airing cupboard instead of the cylinder. Lagging them means the cylinder heats faster and the boiler runs less.
Is 13mm the right wall for 22mm cold pipes in a loft?
For cold loft pipes, a thicker wall gives better frost cover. 13mm suits 22mm pipes inside the heated part of the house.
Can lagging go right up to the boiler?
Keep it back where the boiler instructions ask for clearance. Otherwise run it right up to the fittings so no copper is left bare.
Datasheets
| Length |
2m |
|---|---|
| Delivery Details |
In Store Collection Only |
Only logged in customers who have purchased this product may leave a review.

Reviews
There are no reviews yet.